MK-80 Series of intelligent high frequency switching DC power supply
MK-TX Series of high frequency switching communication power
MKF Series of battery activation equipment
HPLC Series of high-voltage reactive power terminal compensation equipment
HPIC Series of high-voltage reactive power integrative compensation equipment
HPAC Series of high-voltage reactive power automatic compensation equipment
HFPC Series of high-voltage filtering and compensation equipment
HPJK-A series compensation control and protection device
HPJK-L series compensation monitoring and protection device
LPLC Series of low-voltage reactive power terminal compensation equipment
LPAC\LPFC Series of low-voltage reactive power automatic compensation equipment
LFPC Series of low-voltage filtering and compensation equipment
APF Series of Active Power Filter
LPJK Series of compensation control and protection Device
AP1 Series of AC Converter
AJ1 Series of AC motor soft start equipment
AS1 Series of DC motor control equipment
UP Series of uninterrupted AC power supply
Class A agency for SAMWHA Capacitor

MKF Series of battery activation equipment

Select

Overview

MECC PHAYSE developed MKF Series of battery activation equipment, which can activate, charge and inspect batteries automatically.

MKF is composed of Charging Module, Activating Module and Monitoring Module. It can invert energy back to power grid as well as floating or equalizing charging the batteries. Its advanced touching screen monitor can sample the current, capacity and temperature during the activation,  and from which to determine battery's health.

Periodic activation of the battery is to activate the material on active plate of batteries, thus restoring the battery capacity, extending battery life and improving the reliability of emergency DC power supply. MKF is a ideal choice for battery maintenance.

Features

Charging Module adopts new type large capacity IGBT power element as well as advanced PWM pulse duration modulation techniques. Module start/stop controlling, data setting and operating state monitoring can all be realized by communication interface. The output capability of charge module can be up to 50A. It adopts a unique structure which make charge current no relations to the load change of control bus. Even to small capacity battery, stable continuous charge can also be guaranteed without over-charge or under-charge. All Module can be hot plugged or unplugged.

Activating module can activate batteries periodically. It can feedback the energy back to power grid by active inverter, and can effectively activate the battery's plate material, prolonging battery life. And it can calculate the capacity of the battery during activation.

Battery inspection unit can sample each cell's voltage and temperature, and alarm if voltage is abnormal or temperature is too high. And it could remind the user to start equalizing charging the batteries or activating the batteries in order to reduce the internal resistance and increase capacity. If batteries show no improvement after equalizing charging and activating, then replacing the abnormal cell unit can extdisclaimer the life expectation of the whole battery bank.

Besides the standard configuration above, Battery inspection module is available:

Battery inspection module can sample each cell's voltage and temperature, and alarm if voltage is abnormal or temperature is too high. And it could remind the user to start equalizing charging the batteries or activating the batteries in order to reduce the internal resistance and increase capacity. If batteries show no improvement after equalizing charging and activating, then replacing the abnormal cell module can extdisclaimer the life expectation of the whole battery bank.

Condition of Use

Altitude: Less than 1000m (above1000m should adopt plateau-type components)

Temperature: -20℃~+50℃

Humidity : ≤95% (No Condense)

No explosive or flammable medium surrounding; no corrosive gas to damage the insulation and the metal; no conductive dust; No severe vibration and shock at the installation site.

Selection Help

This equipment is intdisclaimered for discharging fixed anti-acid batteries, Valve Regulated Lead-Acid batteries, nickel-cadmium battery.

Rated current for discharge equipment: lead-acid batteries by 0.1C, Ni-Cd battery at 0.2C.

Keywords: MKF cell battery activation lead-acid battery charger inverter

back to top

SHENZHEN MECC PHAYSE ELECTRIC EQUIPMENT CO., LTD
Address: Unit A, 5th Floor, Block TianJing 3.8, Tian'an CheGong Temple Industrial Park,
FuTian District, Shenzhen. Zip Code:518048
Reception: 0755-83584989  Fax: 0755-83866963
Sales Tel: 0755-83866962 (Ms Yan),0755-83586164 (Ms Chen),0755-83866985 (Ms Ma)
Technical Support: 0755-83875432 After-sales service: 0755-83866942 E-mail:market@mecc-phayse.com

Copyright 2002-2011 SHENZHEN MECC PHAYSE ELECTRIC EQUIPMENT CO., LTD. All Right Reserved. 粵ICP備11100910號